Pxie-4162. Contact us with questions for pricing. Pxie-4162

 
 Contact us with questions for pricingPxie-4162  Call the self-calibration function

This file contains installation instructions and compatibility information for Instrument Studio 2022 Q3. PXIe-4147; PXIe-4162; PXIe-4163; Behavior Changes. OCP is triggered when a fault condition occurs that would otherwise cause the device to sink or source current beyond its specifications for an excessive amount of time. Specifications are typical at 25 °C unless otherwise noted. You can also use InstrumentStudio to monitor and control devices being used in external applications, capture data files, export device configuration to other applications, and more. NI-VISA. Initialize the PXIe-4080/4082 for DC Voltage with a range of 100 mV and resolution of 6. With a national network of resources, a robust quality program and broad capabilities, we offer standard and custom solutions to deliver fast, accurate calibration when and how it's needed. Table 1. 1V, 1mA, if force and sensor are disconnected. com | PXIe-4147 SpecificationsThe PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Industries. Aerospace, Defense, &. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. Symbol Description Certification; EU & UK Declarations of Conformity (DoC) PDF KC, EMC: PDFStudy with Quizlet and memorize flashcards containing terms like PXIe-4081, PXIe-4139, PXIe-8880 and more. Contact us with questions for pricing. 如何为我的 SMU 配置电流限制? niDCPower Configure Current Limit Range VI 和 niDCPower Configure Current Limit VI 有什么区别?. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. 2 For increased capability, NI recommends installing the PXIe-4163 in a chassis with slot cooling. Issue Details. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisNI PXIe-4162/4163 Source Measure Units Product Range: SHDB62M-BW-LL Find similar products Choose and modify the attributes above to find similar products. Try searching for what you need. Use the procedures in this document to automate calibration or to conduct manual calibration. The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). For example, force 0. Price may vary with addition of accessories and services. PXIE-4162 CURRENT AND OPEN-SENSE PROTECTION ACCESSORY. The PXIe‑6570 is designed for semiconductor characterization and production test. If the PXI Express chassis has multiple fan speed settings, set the fans to the highest setting. 1 SMU. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The inner shield, located within the outer shield, provides an additional layer of foil insulation tied to the Output LO pin (pin 10). Close the NI. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。ni. Sign In. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. I'm trying to setup a PXIe-4162 to draw -50 uA from a chip, but regardless of the settings I use, the SMU is sinking -130 uA. Manual Trig Routing - SMU-DAQ. PXIe-4163 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 50 mA 30 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Mark as New; Bookmark; Subscribe; Mute; Subscribe to RSS Feed;Download this manual. NI-DCPower 问题详述. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. 2. You can also view context help for the search results. 01-04-2023 10:30 AM. 这允许 SMU 在引脚之间具有高阻抗,因此 Force 和 Sense 没有感测电阻,因为两者都是连续测量的。. The inner shield, located within the outer shield, provides an additional layer of foil insulation tied to the Output LO pin (pin 10). Configuration: •Number of SMU Channels: 24. Maximum altitude 4,600 m (570 mbar) (at 25°C ambient) with chassis fans on high Pollution Degree 2. 2. Part Number: 781743-01, 150660B-02L. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. PXIe-4163. 2. The PXIe-4142 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The PXIe-4162 ships with NI-DCPower driver. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Adding the resistor can impact. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. National Instruments PXIe-4162 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 12 Voltage Range: -24 V to 24 V Current Range: -100 mA to 100 mA Current Sesitivity: 100 pA Source Adapt: Yes Part Number: 785680-01Please contact Artisan Technology Group Sales for configuration pricingPXIe-4162: 786984-01: SHDB62M-DB62M-LL SHDB62M-BW-LL: n/a: PXIe-4163: 786985-01: SHDB62M-DB62M-LL SHDB62M-BW-LL: n/a *Triaxial cables are compatible with the PXIe-4138/4139 if using the SA-413T adapter. View context help in LabVIEW by pressing <Ctrl-H> and hovering over an object. PXIe-4162; PXIe-4163; Behavior Changes. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. The SHDB62M-BW-LL features two conductors that are twisted and encapsulated within. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Industries. Newark offers fast quotes, same day shipping, fast delivery, wide inventory, datasheets & technical support. PXIe-4162; PXIe-4163; Behavior Changes. The following diagram shows a cross-section of the SHDB62M-DB62M-LL when used with a PXIe-4162. 0 has the following requirements: Processor—2. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Adding the. For example, if your base clock runs at 100 MHz, your maximum frequency will be 50 MHz. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. The second card was brand new, and after powering up, I did plug into a board. The DUT shorts to ground. NET Framework 4. Terminal Block, TB-4353, PXIe-4353 PXI Temperature Input Module. Getting Started with the TB-4162. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. You can access the software and documentation known issues list online. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. NI-DCPower 21. 10-20-2022 02:07 PM. 2. NI‑DCPower 19. NI-DCPower 문의사항 공급할 수 있는 전압의 양을 늘리기 위해 NI의 소스 측정 장치 (SMU)를 2개 이상 계단식으로 연결하고 있습니다. The PXIe-4112 is a single-quadrant power supply with two output channels that are capable of identical output. Flexible delivery options, including pick-up and delivery, local drop-off. Provides precise voltage or current sourcing and measurement capabilities for PXI systems. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 问题详述 我想并行连接多个SMU通道,所以我可以增加可用电流量。是否建议将源测量单元并联? 解决方案. Bug Fixes. Return to Home Page; Toggle navigation; Solutions. PXIe-5162 Bandwidth-Limiting Filters Frequency Response, 1 Vpk-pk, Measured 1 –11 –10 –9 –8 –7 –6 –5 –4 –3 –2 –1 0. 5 Current limit set to ≥1 mA and ≥10% of the selected current limit range. NI-DCPower . It helps simplify the task of designing automated test systems for a wide range of applications—from. You can request repair, RMA, schedule calibration, or get technical support. NI‑DCPower 19. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. 6 To settle to 0. Calibration could fail for the following reasons: 1. 5 n olts) 100 n 1 μ 10 μ 100 μ 1 m 10 m 100 m 1 μ 10 μ 100 μ Aperture (Seconds) Re: PXIe-4162 Cannot Reset. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. The PXIe-4163 ships with NI-DCPower driver software, which you can use to program the module. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4162 Quadrant Diagram, Any Channel 60 20 40 0 100 80 ±100 ±24 ±20 ±15 ±10 ±5 0 5 10 15 20 24 ±40 ±60 ±80 ±20 Current (mA) Voltage (V) 2 mA/V 2 mA/V Quadrant II Quadrant III Quadrant IV Quadrant I Valid on any channel in a PXIe-1095 chassis. 4162 Gillie Rd, Victoria, BC V9E 2C7 is currently not for sale. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Refer the NI DC Power Supplies and SMUs Help for more information about. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Due to market conditions delivery times are for general guidance only and may be subject to. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. Self-calibration recalculates certain internal reference values, gains, and offsets to significantly improve accuracy over the full operating temperature range of the device. NI software installs VC2015 Runtime and . 0 (最低限) が必要です。Page 3 PXIe-4162 PXIe-4162 Purpose and Introduction This document explains how to install, configure, and test the PXIe-4162. 0 dropped support for Express VIs in LabVIEW. This is not an exhaustive list of issues fixed in the current version of NI-DCPower. Issues found in this section will not be listed in future. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. Email: info@artisantg. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassisThe following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. Initializing an NI-DCPower session with independent channels allows you to use multiple instruments in the same session. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. Measuring Instruments National Instruments PXIe-4162 Getting Started Manual. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。PXIe, 6 1/2-Digit, +/-300 V, Onboard 1. 416x 的每个力和感测引脚都有一个专用的模数转换器。. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。 From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. 8. You previously purchased this product. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. •Current Range: -50 mA to 50 mA. Disconnect or disable all connections to the PXIe-4162/4163. It also features. Return to Home Page; Toggle navigation; Solutions. Measuring Instruments National Instruments PXIe-4162 Getting Started Manual. Fast Quotes & Shipping. The TB-4162 terminal block is used for screw terminal connections with the PXIe-4162 SMU. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Industries. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. com | PXIe-4147 Specifications PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. The following items are the IDs and titles of a subset of issues fixed in NI-DCPower. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. •Current Sesitivity: 10 pA. Loosen the thumbscrews on the front of the TB-4162 and detach the terminal block from the front of the PXIe-4162. com | PXIe-4162 Specifications PXIe, 12-Channel, ±24 V, 100 mA PXI Source Measure Unit. The 416x have a dedicated analog to digital converter per force and sense pin. 2. Configuration: •Number of SMU Channels: 4. For the purpose of this issue, we only care about the computer in which the PXIe-4162 is. NI-DCPower 21. Please contact Artisan Technology Group Sales for configuration pricing and availability. It also features. Caution The protection provided by the SHDB62M-BW-LL can be impaired if it is used in a manner not described in the user documentation. 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). MLS #. Related Links. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. PXI System Source Measure Units PXIe-4135, PXIe-4136, PXIe-4137, PXIe-4138, and PXIe-4139 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • SourceAdapt digital control loop technology • Four-quadrant source and measure capability • High-speed update. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4163, PXIe-4162, PXIe-4140, PXIe-4141, PXIe-4142, PXIe-4143, PXIe-4144, and PXIe-4145 • Software: Includes interactive soft front panel, API support for LabVIEW and text-based languages, shipping examples, and detailed help files • Four-quadrant source and measure capability • Up to 408 channels in a 4U, 19-inch PXI chassis PXIe-4162 minimum current sink. PXIe-4162. Please refer NI's whitepaper on merging SMU channels. NETクラスライブラリを使用している場合、. Return to Home Page; Toggle navigation; Solutions. The PXIe-4162/4163 SMU differ from other SMUs in architecture. 6. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 8. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. NI PXI Expressスロット冷却能力:38 W、58 W、または82 W. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. PXIe, 2. It also features. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. 2. National Instruments PXIe-4162 Getting Started Manual (20 pages) PXIe, 12-Channel, 24 V, 100 mA PXI Source Measure Unit. The second card was brand new, and after powering up, I did plug into a board. It sounds like you can open a session to a device and use it periodically and after some amount of time the session is invalidated. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Provided are some suggested fixes: The recommended solution is to figure out why Force/Sense lines are not connecting properly to the DUT. NETクラスライブラリを使用している場合、. For the accuracy of the measurement, it will depend on the hardware's specifications: If you are using the device's base clock: refer to the Base clock accuracy. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. For voltage >60 V DC and triaxial connectivity, consider the PXIe-4135 SMU with native triaxial connectors. See all Driver Software Downloads. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Email: info@artisantg. It also features. NETクラスライブラリを使用している場合、. The following table and figure illustrate the voltage and current source and sink ranges of the PXI-4132. The module may be installed into any PXI Express-compatible slot. When attempting to self-test my PXIe-4163 SMU from NI MAX, I see the following error: The self test failed. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Voltage Output and Measurement Connecting and Configuring Equipment for Voltage Verification 1. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). This is not an exhaustive list of issues fixed in the. NI. NI-DCPower . ships with NI-DCPower driver software, which you can use to program the module. Table 1. 9 To recover within ±20 mV after a load current change from 10% to 90% of range. Return to Home Page; Toggle navigation; Solutions. A red blinking light will generally indicate that the power supply to the chassis is out of spec. NI InstrumentStudio 2022 Q1 Readme. NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。The Keysight M9614A is a PXIe 5 channel source / measure unit (SMU). The following list details the hardware models supported in NI-DCPower 17. 概要. 2. Member ‎02-27-2020 09:54 PM. For example, the Active Load current range for the PXIe-6570 is 1. This cable is insulated by an outer layer of Teflon. 1. 2 W-24 V to 24 V:Ambient temperature ranges of 0 °C to 45 °C The PXIe-5162 is warmed up for 15 minutes at ambient temperature Self-calibration is completed after warm-up period Calibration cycle is maintained The PXI Express chassis fan speed is set to HIGH, the foam fan filters are removed if present, and the empty slots contain PXI chassis slot blockers andPXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory—The PXIe-416x Open-Sense Protection Accessory connects to and modifies the behavior of the PXIe-4162 and the PXIe-4163 Source Measure Units (SMUs) when the module is used in remote sense mode. . PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The attached image in your post looks good as long as one of the merged channels is disconnected and you have handled the sessions array appropriately not to turn ON a different channel as. PXIe-4162 Product Certifications. The fast sample rate of the PXIe-4141 can reduce measurement times. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. Refer to the NI website for an up-to-date list of known issues in NI-DCPower 18. 66 lb) typical PXIe-8862 783 g (1. PXIe-4162 configured for normal transient response. NI-488. Optional Items. 5. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. NI-DAQmx. Windows Server 2016 64-bit. The PXIe-5423 is a 40 MHz arbitrary waveform generator capable of generating user-defined, arbitrary waveforms and standard functions including sine, square, triangle, and ramp. Part Number: 784483-01. PXIe-5160/5162 modules can be placed in PXI Express peripheral slots, PXI Express hybrid peripheral slots, or PXI Express system timing slots. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. The SHDB62M-DB62M-LL is optimized for low-leakage and low-thermal electromagnetic fields (EMF) and reduces current leakage when supplying power to the PXIe-4162 and PXIe-4163 PXI Source Measure Units (SMUs). The PXIe-4162/4163 SMU differ from other SMUs in architecture. •Current Range: -100 mA to 100 mA. PXIe-4162 DC Current Source and Sink Ranges, Warranted Chassis Slot Cooling Capacity ≥58 W 38 W 10 μA 100 μA 1 mA 10 mA 100 mA 60 mA 1 The ambient temperature of a PXI system is defined as the temperature at the chassis fan inlet (air intake). Test the chassis with another controller to check if the issue persists. NI-DCPower . 2. These rugged printers deliver advanced connectivity and network protocols, ensuring peace of mind today and a reliable, scalable solution for the long haul. InstrumentStudio allows you to generate and acquire measurements from multiple devices within a single application. Since I need to simulate the whole serially connected stack of battery cells in a battery module, I would like to connect the SMU-s in series, so each SMU will represent one cell. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit. Supported Hardware. Does PXIe-4162 and PXIe-4163 SMUs supports both Current and Voltage cascading similar to the other SMUs? Rgrds. Initialize with channel -> configure -> initialize -> measure -> close. Therefore, your maximum frequency will be half of the base clock frequency you are using. GETTING STARTED GUIDE. Windows 10 64-bit. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Industries. 09-09-2018 11:58 PM. 1. Table of Contents. PXIe-4162 Purpose and Introduction This document explains how to install, configure, and test the PXIe-4162. You can also use InstrumentStudio to monitor and control devices being used in external. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. The 2,992 Square Feet single family home is a 5 beds, 3. 5 GHz, 5 GS/s, 10-Bit PXI Oscilloscope. 3 PXIe-4162/4163ソースメジャーユニットはサポートされていません。. Analog-to-digital converter technology helps you perform high-precision measurements with a current resolution of 100 pA or high. NATIONAL INSTRUMENTS CORP. TB-4162 Specifications. If you need to configure the current limit for your SMU devices, you can use niDCPower Configure Current Limit VI and niDCPower Configure Current Limit Range VI . 8 MS/s. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. This file contains installation instructions and compatibility information for Instrument Studio 2022 Q1. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. National Instruments PXIe-4141 Source Measure Unit (SMU) This item is sealed in the manufacturer's static bag. Is it recommended to connect the Source Measure Units in parallel? Solution It is possible to combine two SMU channels in parallel for higher current, however, this may. 2D Dimensional Drawings. Search for items using the search bar in the upper right corner of the LabVIEW window. Return to Home Page; Toggle navigation; Solutions. Higher power. 概要. The following items are the IDs and titles of a subset of issues fixed in NI-DCPower. This document explains how to install and use the TB-4162 terminal block with a PXIe-4162. It sounds like it's an NI branded controller and chassis. 0 (最低限) が必要です。PXIe-4145 PXIe-4162 PXIe-4163 드라이버. You can connect the PXIe-416x Open-Sense Protection Accessory within a supported PXI. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Ethernet、GPIB、シリアル、USBおよびその他のタイプの計測器をサポートします。. Together, the two modules create a reconfigurable instrument that you can program with. NI-DAQmx. The PXIe‑6570 also includes debugging tools like Shmoo, digital scope, and viewers for history RAM, pin states, and system status. National Instruments PXIe-4162 Source Measure Unit (SMU)Configuration: Number of SMU Channels: 12 Voltage Range: -24 V to 24 V Current Range: -100 mA to 100 mA Current Sesitivity: 100 pA Source Adapt: Yes Part Number: 785680-01Please contact Artisan Technology Group Sales for configuration pricing PXIe-4162 Purpose and Introduction. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help. NI-DCPower . NI-DCPowerは、NIのすべてのプログラマブル電源とSMUと通信するための計測器ドライバです。NI-DCPowerは、IVI (Interchangeable Virtual Instrument) に準拠した計測器ドライバで、電源供給またはSMUの機能を実行する操作とプロパティのセットを提供します。ground through the shell of the PXIe-4162/4163 front panel connector. Touch any metal part of the chassis to discharge static electricity. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. A valid service agreement may be required. 1 Maximum 480 mA per module. Pin View Pane Drive Section; Pin View Pane Active Load Section; niDigital Configure Termination Mode (VI) NI-Digital Pattern Driver Examples. Initialize the PXIe-4080/4082 for DC Voltage with a range of 100 mV and resolution of 6. Do not exceed the isolation voltage of the instrument. It seems really easy but I cannot figure out. Figure 1. Return to Home Page; Toggle navigation; Solutions. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. PXIe-4144 PXIe-4145 PXIe-4162 PXIe-4163 問題敘述 我想並行連接多個SMU通道,讓我可以增加可用電流量。是否建議將電源測量單元並聯? 解決方案. It seems really easy but I cannot figure out. Buy 786984-01 - Ni - Screw Terminal Connector Kit, PXIe-4162 SMU. If I set the PXIe-4162 to draw a higher negative current, say -150 uA, I can measure the current to be exactly -150 uA. It sounds like you can open a session to a device and use it periodically. The information in this document applies to all. This cable is insulated by an outer layer of Teflon. PXIe-4162; PXIe-4163; PXIe-4190; Behavior Changes. This document explains how to install, configure, and test the PXIe-4163. Industries. 0 (minimum) is required. At initialize and reset, several routines are run on the hardware, but I don't think they might be slowly degrading the instrument. The Overcurrent Protection (OCP) has been activated. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. The PXIe-4162 is a 12-Channel, ±24 V, 100 mA source measure unit (SMU). e絡盟 Hong Kong offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. Voltage Measurement Noise vs. 3 No support for PXIe-4162/4163 source measure units. The PXIe‑6570 also includes debugging tools like Shmoo, digital scope, and viewers for history RAM, pin states, and system status. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. I am opening a ticket. 2. 2. No more than 2 channels combined (usually there’s a better alternative > 2 channels). Industries. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Return to Home Page; Toggle navigation; Solutions. Wait two minutes for thermal EMF to stabilize. The module can maximize. It also features. PXIe, 12-Channel, ±24 V, Precision PXI Source Measure Unit - The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. 8 MS/s Isolated Digitizer, L and C Measurement Support, PXI Digital Multimeter. It is possible that we stressed some circuits, but I think we did not. Re: PXIe-4162 and PXIe-4163 andrey. Work with our experts to sustain your critical applications. Caution Shock hazards exist when voltage levels are greater than 30 VRMS, 42. The following items are notable issues fixed between the release of NI-DCPower 2022 Q3 and NI-DCPower 2022 Q4, including additional patches and service packs. 00. Return to Home Page; Toggle navigation; Solutions. 市場投入までの期間がますます短くなりつつある中、多くのチームは製品の品質を管理することに苦労していますが、クラス最高のテスト組織がその道を切り開いています。 PXIe-5162 1 MΩ Frequency Response, 1 Vpk-pk, Measured17 1 –19 –17 –15 –13 –11 –9 –7 –5 –3 –1 Frequency (Hz) 50 k 100 M 200 M 300 M 400 M 500 M 600 M 700 M 800 M ed Amplitude (dB) Figure 6. 0 Kudos Message 1 of 2 (2,358 Views) Reply. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. This module features 4-quadrant operation, integrated remote (4 wire) sensing in each channel for accurate measurements, as well as analog-to-digital converter technology to help you perform high-precision measurements. Allow the PXIe-4162/4163 30 minutes to warm up with the PXI chassis fans set to HIGH. element14 India offers special pricing, same day dispatch, fast delivery, wide inventory, datasheets & technical support. PXIe-5160/5162 Front Panels CH 0 50Ω: 5 Vpk MAX 1MΩ: 42 Vpk MAX CH 1 TRIG CLK IN PFI 0 OUT 1 NI PXIe-5160 500 MHz Oscilloscope CH 0 50Ω: 5 Vpk MAX 1MΩ: 42 Vpk MAX CH 1 CH 2 CLK IN OUT 1 NI PXIe-5160 500 MHz Oscilloscope CH 3 Note PXIe-5160 shown. Additional derating applies to sinking power when operating at an ambient temperature of >45 °C. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. PXIe-4162 DC 電流ソースとシンクレンジ (保証) シャーシスロット冷却能力 ≥58 W 38 W 10 µA 100 µA 1 mA 10 mA 100 mA 60 mA PXIe, 1. PXIe-4162/4163 SMU 在架构上不同于其他 SMU。. 技術的な問題のトラブルシューティングや推奨製品から、見積りと注文まで、弊社がお手伝いいたします。PXIe-4162/PXIe-4163 SMU Open Sense Resistor Accessory. It features 4-quadrant operation, and each channel has integrated remote (4-wire) sensing for accurate measurements. measurements, as well as analog-to. The PXIe-4162 (Part Number: 785680-01) is a unit of estimation of high-density source (SMU)-the device is equipped with 12 SMU channels. The PXIe-4162 is a high-precision, high-density source measure unit (SMU) with 12 identical SMU channels. 0 (minimum) is required. You can pair the PXIe‑7962 with FlexRIO adapter modules that offer high-performance analog and digital I/O. Academic and Research; Aerospace, Defense, and Government; Electronics; Energy; Industrial Machinery; Life Sciences. Added support for the PXIe-5110, PXIe-5111, and PXIe-5113 oscilloscopes, newly supported in NI-SCOPE 18.